Bonington Theatre


Edit this theatre

Contact Information

Address
High Str, Arnold
Town
Nottingham
County
Nottinghamshire
Postcode
NG5 7EE
Email
info@bonington-theatre.co.uk
Main Contact
0115 9670114
Company Manager
 
Box Office
0115 9670114
General Admin
0115 9670114
Stage Door
0115 9670114
Fax
0115 9560731
Website
www.bonington-theatre.co.uk
Website Technical Page
 

Theatre Staff

Technical Manager
Bob Massey
Chief Electrician
 
Sound Technician
David Gotham
Stage Manager
 
Stage Carpenter
 
Flyman
 
Wardrobe Contact
 
FOH Contact/Manager
Sue Scott
Accomodation list is available from
Theatre and bonington web site
 
 
 

Stage Details (all dimensions are in metres.)

Type of stage (pros, thrust etc)
Pros or arena
Rake
no
Surface
wood block
Is drilling or other fixing allowed?
no
Type of flying system
hand line
Total number of lines
4
Barrel (pipe) diameter
37mm
Barrel length
7m
Max load rating per set
250kg/150kg
Maximum out dead
 
Overall load rating
 
Spacing between lines
2m
Distance of first available set of lines from US side of pros
2m
Apron Width
7m
Apron Depth
1m
Traps/Size
none
Weight Restrictions
 
Are stage plans available? If so, where from?
Bonington Theatre
or web site

Stage Management facilities

Prompt corner pos.
up stage left
FOH call facilities?
yes
Q-Lights?
talk
Bar Bells?
yes
Q-Lights Movable?
yes
First aid box?
yes

Overall Dimensions

Size of Prosc:

Width
7m
Height
5.5m

Wing Space:

Stage Left
1.5m/3m
Height of Grid
6m
Stage Right
1.5m
Setting line to rear of prosc
6m
Setting line to front edge of stage
1m
Setting line rear wall
7m

Are these available?

House tabs
yes
Cyc.
yes

Blacks:

Borders
yes
Legs
yes
Tabs
yes

Unusual or unexpected features

eg) Get in - height, drop, ramp etc...
first floor up straight stairs or small lift

LX & Sound Details

Power available and location:

Lighting
2 x100amp 3 phase ( on stage and control room)
Sound
26amp

LX & Sound Details

Additional power supplies available:
32 amp single phase on stage and control room
Lighting Control
72 way eclipse 500 mem and chase 6 dim ind

Number of dimmers and ratings:

On stage
24+4 dimmers
FOH
48
Any patching/twinning
all patched

Lanterns available in fixed location:

Profiles
25
Fresnels
40
Cyc Floods
9
Follow Spots
1
Movable lanterns list
3 floods 1kw and 6x 500w
4 x 1kw pc
14 x 650w fresnel
6 x patt23
 
Rigging (Tallescope/ladder etc)
tower

Sound

Indication of tie lines
10 mike 4 tie 4 fold back
Mixer position
control room or auditorium
Equipment available
10 mikes and stands
2 powered and 4 unpowered monitors
fixed foh speakers
 
 
Headset/comms details
talk back via head sets x4 or fixed units to sm and control
 

Accomodation

Dressing rooms
2
Showers & toilets
2
Access to stage
spiral stairs
Wardobe facilities
washing machine
 
Wig room & facilities
no

Orchestra

Pit size (permanent or variable)
none

Equipment Available

Lit music stands
none
Chairs
100
Net
 
Rostra
1
Double bass pin boards
none
Sound baffles
none

Orchestra Accomodation

Band Rooms
extra room available by arrangement

Other

Any other features
stage is flat floor with raked seating. this is retractable and shows can be in round or club style with tables and chairs. seating in club style 120 or fixed seating 176

Change History: Authorised27-Sep-2004

back to Theatre Listing

  • Technical Information on Theatres
  • Safety Matters
  • Books and Guidance Notes
  • Codes, Forms and Updates
  • Theatre Essentials
  • FAQs
  • Links
  • Freelancers
Worldpay Logo

Safe and Secure Online Shopping

Follow us on Facebook
© 2025 The Association of British Theatre Technicians  55 Farringdon Road, LONDON, EC1M 3JB United Kingdom
Tel: +44 (0)20 7242 9200    Fax: +44 (0) 20 7242 9303    Email: info@abtt.org.uk

Sitemap - Accessibility - Terms and Conditions - Data Protection Act Code of Practice

realnet - websites that perform