CHRIST'S HOSPITAL THEATRE


Edit this theatre

Contact Information

Address
Christ's Hospital
Town
Horsham
County
Sussex
Postcode
RH13 7LW
Email
-
Main Contact
01403 269437
Company Manager
 
Box Office
-
General Admin
-
Stage Door
-
Fax
01403 211580
Website
 
Website Technical Page
 

Theatre Staff

Technical Manager
 
Chief Electrician
Same as above
Sound Technician
" "
Stage Manager
" "
Stage Carpenter
" "
Flyman
" "
Wardrobe Contact
-
FOH Contact/Manager
same as above
Accomodation list is available from
Jackie Davies / Box office
 
 
 

Stage Details (all dimensions are in metres.)

Type of stage (pros, thrust etc)
 
Rake
 
Surface
 
Is drilling or other fixing allowed?
 
Type of flying system
 
Total number of lines
 
Barrel (pipe) diameter
2
Barrel length
8.3m
Max load rating per set
250 kg
Maximum out dead
-
Overall load rating
-
Spacing between lines
Varied Fixed Points
Distance of first available set of lines from US side of pros
-
Apron Width
-
Apron Depth
-
Traps/Size
-
Weight Restrictions
-
Are stage plans available? If so, where from?
Technical office
 

Stage Management facilities

Prompt corner pos.
Mobile
FOH call facilities?
YES
Q-Lights?
YES
Bar Bells?
YES
Q-Lights Movable?
YES
First aid box?
YES

Overall Dimensions

Size of Prosc:

Width
-
Height
5.67m

Wing Space:

Stage Left
2.10 m
Height of Grid
10m
Stage Right
2.10 m
Setting line to rear of prosc
Performance space : 15.18 m ( 49'10
Setting line to front edge of stage
11.58m ( 38'0
Setting line rear wall
 

Are these available?

House tabs
YES
Cyc.
YES

Blacks:

Borders
YES
Legs
YES
Tabs
YES

Unusual or unexpected features

eg) Get in - height, drop, ramp etc...
NONE

LX & Sound Details

Power available and location:

Lighting
600 A red phase
Sound
30 A yellow phase

LX & Sound Details

Additional power supplies available:
200 A 3 phase 32A 3 phase
Lighting Control
Strand M24

Number of dimmers and ratings:

On stage
62
FOH
29
Any patching/twinning
YES

Lanterns available in fixed location:

Profiles
-
Fresnels
-
Cyc Floods
-
Follow Spots
-
Movable lanterns list
46 profiles
39 fresnels
24 floods + 5 battens
1 followspot
14 pals
Rigging (Tallescope/ladder etc)
YES

Sound

Indication of tie lines
7 SL / 7SR / 4DS
Mixer position
BT Floor control room
Equipment available
mixer, amps, speakers
mics, tape decks, cd
players, cassette decks
Record decks, FX units
 
Headset/comms details
TEC pro comm system
 

Accomodation

Dressing rooms
2
Showers & toilets
YES
Access to stage
YES
Wardobe facilities
ironing
 
Wig room & facilities
 

Orchestra

Pit size (permanent or variable)
6.6m wide 6.6m deep

Equipment Available

Lit music stands
none
Chairs
40
Net
NO
Rostra
YES
Double bass pin boards
none
Sound baffles
none

Orchestra Accomodation

Band Rooms
available in separate location

Other

Any other features
Performance Space: 15.18m width
11.58m depth

back to Theatre Listing

  • Technical Information on Theatres
  • Safety Matters
  • Books and Guidance Notes
  • Codes, Forms and Updates
  • Theatre Essentials
  • FAQs
  • Links
  • Freelancers
Worldpay Logo

Safe and Secure Online Shopping

Follow us on Facebook
© 2025 The Association of British Theatre Technicians  55 Farringdon Road, LONDON, EC1M 3JB United Kingdom
Tel: +44 (0)20 7242 9200    Fax: +44 (0) 20 7242 9303    Email: info@abtt.org.uk

Sitemap - Accessibility - Terms and Conditions - Data Protection Act Code of Practice

realnet - websites that perform